Reinforcement and render
Reinforcement should:
- be detailed in the design and be in accordance with the
manufacturer’s recommendations
- be formed with appropriate trim at openings, corners, angles,
interfaces and movement joints
- include additional mesh where there may be increased stress
in the render system, i.e. at the corners of window or
door openings
- be lapped to a minimum of 100mm.
Render should:
- not be applied where the surface has contamination,
dust or loose particles
- have the appropriate number and thickness of coats in
accordance with the manufacturer’s recommendations
- be mixed to ensure colour consistency where coloured
pigments are specified
- be specified and used with the appropriate trims to form
corners, returns and features in accordance with the
manufacturer’s recommendations.