Two coat plaster system for use with metal lathing when bridging steel columns, beams and lintels for wall locations comprising of 11mm Thistle HardWall (undercoat) and 2mm ThistlePro PureFinish (finish coat).
The PL0041 specification outlines a two coat plaster system designed specifically for metal lathing applications, particularly useful when bridging structural elements such as steel columns, beams, and lintels in wall locations. The system consists of an 11mm undercoat using Thistle HardWall, followed by a 2mm finish coat with ThistlePro PureFinish. This combination not only provides structural support but also ensures a smooth, aesthetically pleasing surface for various applications.
To achieve a high-quality finish, it's essential to collaborate with the design team or contractor prior to the application of the skim coat. Discussing aspects such as the quality of finish, flatness, and various design considerations will help ensure that the plaster meets the acceptance criteria, especially under specific lighting conditions. Proper attention to these details can significantly enhance the overall appearance and performance of the plaster work.
The recommended products for this system include a pre-treatment of Thistle GypPrime, along with the aforementioned finish and undercoat materials. Utilizing these specific products ensures compatibility and optimal performance, making it easier to achieve the desired results in your plastering projects.
Moreover, the SpecSure® system performance warranty provides assurance that all components will perform as intended throughout the building's life. To protect this warranty, all materials must be specified and installed according to British Gypsum's guidelines. Always consult the design team before making modifications to ensure that the assembly remains compliant and effective for the project’s specifications. For further details, refer to the British Gypsum website for comprehensive installation guidance and warranty information.
Specification: PL0041
Two coat plaster system for use with metal lathing when bridging steel columns, beams and lintels for wall locations comprising of 11mm Thistle HardWall (undercoat) and 2mm ThistlePro PureFinish (finish coat).
Finish Quality
Prior to applying skim coat, liaise with the design team/contractor on site to determine quality of smooth finish, flatness, and the design considerations for work and acceptance of smooth plaster finishes under aspects of lighting.
Finish coat pre-treatment | Thistle GypPrime |
Finish coat | 2mm of ThistlePro PureFinish |
Undercoat | 11mm of Thistle HardWall |
Other Requirements
SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.